01
CAFS: Advanced MV Cable Alerting and Fault Spotting by China's Leading Suppliers and Factory
Functional Features
New monitoring methods: High-frequency digital signal spectrum comprehensive analysis method and dual end measurement method.
Fault location: Using the principle of traveling wave distance measurement, precise fault location can be achieved, with a fault distance measurement accuracy of ± 2.5 meters.
Fault line selection: Using the principle of traveling wave line selection, fault circuit line selection is carried out for cable insulation.
Circulation monitoring: Real time monitoring of the insulation condition of the outer sheath of the line. By using digital spectrum analysis methods, the capacitive current, resistive current, and fault arc current of the cable are calculated separately, and the circulation curve is drawn. Fault alarms are given for cable lines with abnormal outer sheath insulation.
Fault warning: Three-level warning based on cable operation status.
Products Advantage
Partial discharge monitoring, signal acquisition and transmission: On-site acquisition and conversion into optical signals, without interference and attenuation, ensuring accuracy from the source.
Lightning protection and anti-interference technology: Exclusive patent of Enrely, validated in the market for nearly 10 years with significant results.
Sampling frequency: Only 100MHz (hardware and software integration).
CAFS: No monitoring blind spots.
Detail Pictures
Frequently Asked Questions (FAQ)
Q1
What new monitoring methods does the system implement?
The system utilizes a high-frequency digital signal spectrum comprehensive analysis method along with a dual end measurement method for advanced cable monitoring.
Q2
How accurate is the fault location measurement?
By applying the principle of traveling wave distance measurement, the system locates faults precisely with an accuracy within ± 2.5 meters.
Q3
How does the system perform circulation monitoring?
It monitors the outer sheath insulation in real time. By using digital spectrum analysis, it calculates the capacitive, resistive, and fault arc currents separately to draw a circulation curve and trigger alarms for anomalies.
Q4
What is the advantage of the signal acquisition process?
Signals are acquired on-site and instantly converted into optical signals. This prevents signal interference and attenuation, ensuring high measurement accuracy directly from the source.
Q5
Is the lightning protection technology field-proven?
Yes, the lightning protection and anti-interference technology is an exclusive patent of Enrely, which has been validated in the market for nearly 10 years with proven performance.
Q6
Are there any monitoring blind spots with CAFS?
No, the CAFS system is designed to ensure there are no monitoring blind spots across the cable line installation.