Leave Your Message
Products Categories
Featured Products

China AHF Suppliers: Factory Equipment for Effective Harmonic Control in Electrical Networks

In addressing the critical issue of power harmonic pollution, the Active Harmonic Filter (AHF) stands out as the most effective solution for enhancing power quality. This innovative equipment is developed using cutting-edge power electronics and digital signal processing technologies, leveraging high-speed DSP processing devices. The AHF functions as a harmonic current generator, skillfully tracking harmonic components in the current and generating equal amplitude harmonic currents with opposite phases to combat power harmonics.

,

The AHF system is composed of two main parts: the instruction current operation circuit and the compensation current generation circuit. The instruction current operation circuit performs real-time detection of electrical currents, converting analog signals into digital formats for processing by a high-speed digital processor (DSP). It effectively separates harmonic and fundamental currents to derive the instruction current, which is then transmitted to the compensation current generation circuit. This is achieved through a pulse width modulation (PWM) signal facilitated by the current tracking control and drive circuits.

,

Using advanced IGBT and IPM power modules, the AHF generates a compensation current that mirrors the harmonic current in amplitude and opposes its polarity. This harmoniously injected current neutralizes the existing harmonic currents in the power grid, actively eliminating power harmonics and ensuring a dynamic, rapid, and comprehensive harmonics management solution. As a leading manufacturer and supplier in China, our factory is committed to providing state-of-the-art active harmonic filters to meet the growing demands for improved power quality in various applications.

    Industrial Applications

    AHF is suitable for industrial high-capacity loads, such as rectifiers, frequency converters, large UPS, arc furnaces, intermediate frequency furnaces, three-phase chargers, and other three-phase load scenarios.

    Commercial Applications

    Suitable for single-phase nonlinear loads in commercial buildings, such as energy-saving lamps, computers, UPS, elevators, variable frequency air conditioners, etc., which generate third harmonic and heat up the N-line.

    Technical Indicators

    Item 400V 660V
    Current rating 50A 100A 135A 50A 100A
    Voltage level 380V, 440V, 480V 600V, 660V, 690V
    Voltage range -20%~+15%
    Frequency 50/60Hz±5%
    Phases 3 phase 3 wire, 3 phase 4 wire
    Response time ≤10us
    Parallel operation Unlimited, Max 6 modules for one SAM controller
    Overload capability 110%, 1 minute
    Efficiency ≥97.5%
    CT location Grid side or Load side
    Function Harmonics, reactive power, unbalance compensation
    Harmonics Up to 50th order
    Communication Modbus, TCP/IP, IEC61850, others upon request

    Product Advantages

    Thermal design and structural optimization based on precise models.

    Miniaturization, occupying less space.

    Compensation for specified harmonic frequencies, adjustable inductive and capacitive reactive power compensation system, automatic detection of unbalanced loads, suppression of system resonance, and full function monitoring system.

    Increased operational efficiency by avoiding unplanned stops.

    Lower losses in the transformer.

    Prolonged equipment lifetime.

    Standard compliance.

    Frequently Asked Questions

    What applications are suitable for Active Harmonic Filters (AHF)?

    AHF is highly suitable for industrial scenarios with high-capacity loads like rectifiers, frequency converters, large UPS, and arc furnaces, as well as commercial buildings with single-phase non-linear loads like computers, elevators, and variable frequency air conditioners that cause N-line heating.

    What are the key technical indicators of the 400V and 660V AHF models?

    The 400V model supports voltage ranges of 380V, 440V, and 480V with current ratings of 50A, 100A, and 135A. The 660V model supports voltage ranges of 600V, 660V, and 690V with current ratings of 50A and 100A.

    How fast does the AHF respond to load changes?

    The AHF features an ultra-fast response time of ≤10 microseconds (us), ensuring rapid mitigation of power quality issues.

    Can I run multiple AHF modules in parallel?

    Yes, parallel operation capability is unlimited. You can connect up to 6 modules under a single SAM controller for easy system expansion.

    What specific power issues does the AHF compensate for?

    The system provides comprehensive compensation for harmonics (up to the 50th order), reactive power (both inductive and capacitive), and three-phase load unbalance.

    How does the AHF improve operational efficiency and equipment lifetime?

    By suppressing harmonics and reducing system resonance, the AHF avoids unplanned stops, lowers heat losses in transformers, and prevents premature aging of connected equipment.

    Leave Your Message