01
China DCES Multi-Functional Electrical Safety Device for Variable-Frequency Drive Protection - Factory Suppliers
Functional features
DCES can effectively compensate for 100% voltage sag.
DCES can effectively address voltage transient problems caused by various power system faults such as single-phase short circuits, interphase short circuits, and three-phase short circuits.
DCES can achieve rapid response of the entire machine within 5ms, and the entire compensation process does not affect the operation of sensitive loads.
DCES can be customized according to user requirements for compensation time, load capacity, and other parameters.
After DCES is turned on, the program will self check and the entire process does not require human intervention. DCES communicates with the user‘s DCS fieldbus through the RS485 interface, uploading the status of the DCES equipment itself and the power supply situation of the power system.
products advantage
Segmented synthesis, real-time online, and rapid monitoring technology for AC bus voltage fluctuations and inverter DC voltage fluctuations.
Real time detection of multiple loads and independent protection technology.
Multiple load independent feedback, separate control, and branch output technology.
Intelligent energy management technology can increase shaking protection time by up to 3000%.
Supports up to 4 AC bus voltage fluctuations for simultaneous monitoring.
Supports up to 96 independent outputs.
detail pictures
Frequently Asked Questions
What level of voltage sag can DCES compensate for?
DCES can effectively compensate for up to 100% voltage sag.
How fast does the DCES system respond to power faults?
The DCES system achieves a rapid response of the entire machine within 5ms. The entire compensation process is designed to run smoothly without affecting the operation of sensitive loads.
What types of power system faults can DCES address?
DCES can effectively address voltage transient problems caused by various power system faults, including single-phase short circuits, interphase short circuits, and three-phase short circuits.
Can the DCES system be customized for specific applications?
Yes, DCES can be fully customized according to user requirements for compensation time, load capacity, and other operational parameters.
How does DCES communicate with the site's control system?
DCES communicates with the user's DCS fieldbus through the RS485 interface, uploading the status of the DCES equipment itself and the power supply situation of the power system.
How many independent outputs and AC buses can DCES support?
DCES supports up to 96 independent outputs and can simultaneously monitor up to 4 AC bus voltage fluctuations.