01
China DCES Multifunctional Electrical Safety Device for Variable-Frequency Drive Protection | Suppliers & Factory
Functional features
- DCES can effectively compensate for 100% voltage sag;
- DCES can effectively address voltage transient problems caused by various power system faults such as single-phase short circuits, interphase short circuits, and three-phase short circuits;
- DCES can achieve rapid response of the entire machine within 5ms, and the entire compensation process does not affect the operation of sensitive loads;
- DCES can be customized according to user requirements for compensation time, load capacity, and other parameters;
- After DCES is turned on, the program will self check and the entire process does not require human intervention. DCES communicates with the user‘s DCS fieldbus through the RS485 interface, uploading the status of the DCES equipment itself and the power supply situation of the power system.
products advantage
- Segmented synthesis, real-time online, and rapid monitoring technology for AC bus voltage fluctuations and inverter DC voltage fluctuations;
- Real time detection of multiple loads and independent protection technology;
- Multiple load independent feedback, separate control, and branch output technology;
- Intelligent energy management technology can increase shaking protection time by up to 3000%;
- Supports up to 4 AC bus voltage fluctuations for simultaneous monitoring;
- Supports up to 96 independent outputs.
detail pictures
Frequently Asked Questions (FAQ)
How effectively does the DCES compensate for voltage sags?
DCES can effectively compensate for 100% voltage sag, providing robust protection against power fluctuations.
What is the response time of the DCES system?
The DCES achieves a rapid system-wide response within 5ms. The entire compensation process is designed to ensure that the operation of sensitive loads remains unaffected.
Can the DCES system be customized for specific applications?
Yes, the DCES can be customized based on specific user requirements, including parameters such as compensation time and load capacity.
How does the DCES communicate with existing plant systems?
DCES communicates directly with the user's DCS fieldbus via an RS485 interface. It automatically uploads the status of the DCES equipment and the power system's supply status.
How many monitoring channels and outputs does the DCES support?
The DCES supports simultaneous monitoring of up to 4 AC bus voltage fluctuations and can accommodate up to 96 independent outputs.




