01
China RONS Lightning and Interference Recording Analyzer – Reliable Suppliers and Factory for Nanosecond Overvoltage Solutions
Functional Features
| No. | Feature Item | Technical Description |
|---|---|---|
| 1 | Beidou/GPS timing | Can be connected to a separate external time synchronization device or shared with the original system clock. |
| 2 | Transient overvoltages | Continuous for several milliseconds or less, strong resistance oscillation or non-oscillation overvoltage, exceeding the set threshold, recording (-1~+30s). |
| 3 | Slow-front overvoltage | Most are unipolar, with peak values ranging from 20ms to 5ms, and half peak values less than 20ms. When the amplitude of the overvoltage exceeds the set threshold, the waveform is recorded (-1~+30s). |
| 4 | Switching overvoltage | Most are unipolar, with peaks ranging from 250ms to 2.5ms. When the amplitude of the overvoltage exceeds the set threshold, the waveform is recorded (-1~+30s). |
| 5 | Fast-front overvoltage | Most are unipolar, with a wavefront of 0.1ms~20ms and a half peak of less than 300ms. If the set threshold is exceeded, the waveform is recorded (-1~+30s). |
| 6 | Lightning | Most are unipolar, with a peak value between 20ms and 5ms. If the set threshold is exceeded, the waveform will be recorded (-1~+30s). |
| 7 | Other overvoltage | Various common transient overvoltage monitoring methods typically last for a long time and are recorded when the set threshold is exceeded (-1~+30s). |
| 8 | Routine power quality monitoring | Voltage fluctuation, load current, power analysis, THD monitoring, imbalance monitoring, etc. No need to install other power quality monitors. |
| 9 | Main spec | Sampling frequency 100MHz; monitor 0-63 harmonics, inter harmonics, and higher harmonics; 4G memory, 64G solid-state drive; LCD high brightness TFT LCD touch screen; 10 inches; Resolution 800 × 600; 1 × RS-232/485, 1 × RS232, 4 × USB2.0, 1 × VGA, 1 × GigaLAN. |
Products Advantage
A high sampling frequency of 20MHz
Simultaneously equipped with power quality monitoring function
Fill the prevention and control blind spots, accurately capture nanosecond level details
Powerful data analysis and networking capabilities
Frequently Asked Questions
Q
How does the timing synchronization function on this device?
The system supports Beidou/GPS timing synchronization and can be connected to a dedicated external synchronization unit or share time signals directly with the existing system clock.
Q
What types of overvoltage events are monitored and recorded?
It monitors transient overvoltages, slow-front, switching, fast-front, lightning strikes, and other general overvoltages, automatically recording waveforms within a range of -1s to +30s upon exceeding thresholds.
Q
Is an extra power quality analyzer required?
No extra equipment is needed. The device natively includes routine power quality monitoring functions such as voltage fluctuation, load current, power analysis, THD, and imbalance monitoring.
Q
What harmonics measurement capability does the system offer?
It has a 100MHz main sampling rate capable of monitoring 0 to 63 harmonics, inter-harmonics, and higher-order harmonics simultaneously.
Q
What hardware and communication interfaces are integrated?
The hardware includes a 10-inch 800×600 TFT touch display, 4GB RAM, 64GB SSD, 1×RS-232/485, 1×RS-232, 4×USB 2.0 ports, 1×VGA, and 1×Gigabit LAN port.