China TOVS Power Interference Suppression Device - Multifunctional Lightning and Overvoltage Protection from Reliable Suppliers and Factory
Functional Features
Over 90% attenuation of overvoltage caused by lightning strikes, operation, resonance, etc.
Simultaneously solving various problems such as normal interference and transient interference.
Does not conflict with SPD, and the original system can remain unchanged.
TOVS is generally installed in the output of UPS to clear its interferences.
The maximum amplitude is limited to below 370V, which is the peak value of 260V.
The interference attenuation efficiency is greater than 90%.
TOVS can fill the huge protection blind spot of SPD.
TOVS can also be installed on the input end of UPS for protection.
TOVS has multiple overvoltage protection functions to ensure the safety of electrical equipment.
When there is a minor malfunction in the TOVS device, the device has a fault alarm function, and the [Alarm] indicator light is on for maintenance personnel to check. The TOVS device has an alarm and some functions are missing. The main functions are still effective and do not affect the safe and reliable operation of the load.
Technical Indicators
| Suppression frequency range | 75Hz~100MHz |
|---|---|
| Maximum suppression current | 120kA (8/20us) |
| Maximum suppression voltage | 25kV(8/20us) |
| Continuous operating current | ≤20A |
| Loss | <60W |
| Interference suppression rate | 50%~96% |
| Response time | <25ns |
| Resistance measurement range | 0-200Ω |
| Measurement accuracy | ±2.5% |
Detail Pictures
Frequently Asked Questions
What level of overvoltage attenuation does TOVS provide?
TOVS provides over 90% attenuation of overvoltage caused by lightning strikes, operating actions, resonance, and other electrical disturbances.
Can TOVS be integrated with existing Surge Protective Devices (SPDs)?
Yes. TOVS does not conflict with existing SPDs, allowing your original system setup to remain unchanged while successfully filling the protection blind spots of traditional SPDs.
Where is the recommended installation point for TOVS?
TOVS is typically installed at the output end of a UPS to eliminate output interferences. Additionally, it can also be installed at the input end of a UPS to provide comprehensive front-end protection.
What happens if a minor malfunction occurs in the TOVS device?
If a minor malfunction occurs, the fault alarm function activates the [Alarm] indicator light to alert maintenance personnel. Although some secondary features might be limited, the main protective functions remain active and do not affect the safe operation of the load.
What are the core technical capabilities of TOVS?
TOVS operates with a response time of less than 25ns, supports a maximum suppression current of 120kA (8/20us), and limits the maximum suppression voltage to 25kV (8/20us) within a frequency range of 75Hz to 100MHz.