Dynamic Reactive Power Compensation SVG by China Suppliers and Factory - Enhance Power Quality Efficiently
Technical Indicators
| Item | SVG Modules |
|---|---|
| Capacity rating | 50kvar, 100kvar |
| Voltage level | 400V~35kV |
| Voltage range | -20%~+15% |
| Frequency | 50/60Hz±5% |
| Phases | 3 phase 3 wire, 3 phase 4 wire |
| Response time | ≤1ms |
| Parallel operation | Unlimited, Max 6 modules for one SAM controller |
| Overload capability | 110%, 1 minute |
| Efficiency | ≥97.5% |
| CT location | Grid side or Load side |
| Function | Reactive power, unbalance and harmonic compensation |
| Harmonics | Max 10% filtering capability (up to 13th order) |
| Target power factor | -1.0~+1.0, upon customer request |
Products Advantage
| Conventional Technology | SVG (Static Var Generator) |
|---|---|
| Overcompensation or undercompensation | Stepless and accurate compensation |
| Cannot compensate capacitive reactive power | Capacitive and inductive compensation |
| Slow response speed | Very fast response speed (≤1ms) |
| Low unbalance regulation capability | Freely load unbalance compensation |
| Uncontrollable harmonic filtering capability | Optional active filtering setting |
| Harmonic resonance problem | Suppress resonance |
| Complex capacity expansion | Modular design and easy expansion |
| High surge current | No surge current |
| High space required | More compact |
Frequently Asked Questions
What capacity ratings and voltage levels are available for the SVG modules?
SVG modules are available in capacity ratings of 50kvar and 100kvar, supporting a wide range of voltage levels from 400V up to 35kV.
How fast is the response time of the SVG module?
The SVG module features an exceptionally fast response time of ≤1ms, which is significantly faster than conventional technology.
Can multiple SVG modules be operated in parallel?
Yes, parallel operation is unlimited. You can connect a maximum of 6 modules for one SAM controller to meet your capacity expansion needs.
How does SVG perform in terms of harmonic resonance and filtering?
Unlike conventional technology which suffers from harmonic resonance, SVG suppresses resonance and offers optional active filtering settings with up to 10% filtering capability (up to the 13th order).
What target power factor can the SVG module achieve?
The SVG module can achieve a target power factor ranging from -1.0 to +1.0, which can be configured upon customer request.
What makes SVG superior to conventional reactive power compensation?
SVG provides stepless and accurate compensation, supports both capacitive and inductive compensation, features no surge current, handles load unbalance freely, and has a much more compact, modular design.


