01
GIMS: Advanced Ground Distributed Lightning & Interference Solutions for MV/LV by China Suppliers and Factory
Function Features
Ground potential counterattack overvoltage suppression
Ground interference suppression
Grounding current monitoring
Grounding current FFT analysis
Grounding impedance monitoring
Ground impedance exceeding limit alarm
Ground potential monitoring
Ground potential exceeding limit alarm
GIMS continuously monitors the ground network in real-time and can share the monitored data with third-party platforms, providing strong data support for future fault analysis.
Technical Indicators
| Working power supply | 220VAC |
| Interference suppression frequency range | 75Hz~100MHz |
| Depression ratio | 50%~96% |
| Maximum suppression voltage | 25kV (Transient) |
| Maximum suppression current | 320kA (Transient) |
| Normal loss | ≤ 60W |
| Resistance measurement range | 0~200Ω |
| Protection time accuracy | 0.001s |
| Response time | < 25ns |
| Measurement accuracy | ±2.5% |
| Protection grade | IP20 |
Detail Pictures
Frequently Asked Questions
Q: What is the primary function of the GIMS system?
The GIMS system provides comprehensive ground potential counterattack overvoltage suppression, interference suppression, real-time grounding current and impedance monitoring, FFT analysis, and limit alarms to safeguard electrical networks.
Q: What are the surge suppression capabilities of this device?
The unit offers transient protection capable of handling a maximum suppression voltage of up to 25kV and a maximum suppression current of up to 320kA, with an ultrafast response time of less than 25ns.
Q: What interference frequency range can the system suppress?
The system effectively suppresses ground interference across a broad frequency range of 75Hz to 100MHz, achieving a depression ratio of 50% to 96%.
Q: What is the resistance measurement range and accuracy?
The device accurately monitors grounding resistance within the range of 0 to 200Ω with a high measurement accuracy of ±2.5% and a protection time accuracy of 0.001s.
Q: Can GIMS integrate with third-party monitoring platforms?
Yes, GIMS continuously monitors the ground network in real-time and seamlessly exports and shares monitored data with third-party management platforms for comprehensive fault diagnosis and analysis.
Q: What are the power supply requirements and protection rating?
The system operates on a standard 220VAC power supply, maintains low power consumption with normal loss of ≤ 60W, and is housed in an IP20-rated protective enclosure.