Leave Your Message
Products Categories
Featured Products

High-Precision RAVS Monitoring Device for Transient Faults - China Suppliers & Factory for Voltage Fluctuation Analysis

The RAVS is an advanced monitoring device designed for the real-time, long-term, and high-frequency recording of sudden changes in system voltage. As one of the leading products from China suppliers, the RAVS excels in monitoring system voltage fluctuations and assessing power quality. This device boasts high accuracy, precision, response speed, and stability, making it a preferred choice among factories that require reliable voltage monitoring solutions. Choose RAVS for unparalleled performance in voltage analysis and ensure optimal operational efficiency.

    Functional Features

    1

    Beidou/GPS timing

    Can be connected to a separate external time synchronization device or shared with the original system clock.
    2

    Voltage flicker

    If the difference between the maximum peak values of the two adjacent wave heads of the voltage waveform exceeds the set threshold, immediately start recording (-1 ~ +30s).
    3

    Voltage sag

    If the voltage of any phase is lower than the set threshold, immediately start recording (-1 ~ +30s).
    4

    Voltage oscillation

    Oscillation is difficult to prevent and poses serious harm. When the oscillation amplitude exceeds the set threshold, immediately start recording (-1 ~ +30s).
    5

    Voltage deviation

    The transient voltage waveform contains a DC component, and when the amplitude exceeds the set threshold, the recording is immediately initiated (-1 ~ +30s).
    6

    Voltage surge

    External surge, power transmission, protrusion, sudden load rejection, etc., exceeding the set threshold, immediately start recording (-1 ~ +30s).
    7

    Voltage grounding

    When a single-phase grounding fault occurs in the system, accurately identify the fault and its occurrence time, and immediately start recording (-1 ~ +30s).
    8

    Voltage short circuit

    When a phase to phase short circuit fault occurs in the system, accurately identify the fault and its occurrence time, and immediately start recording (-1 ~ +30s).
    9

    Routine power quality monitoring

    Voltage fluctuation, load current, power analysis, THD monitoring, imbalance monitoring, etc. No need to install other power quality monitors.
    10

    Main spec

    Sampling frequency 100kHz; monitor 0-63 harmonics, inter harmonics, and higher harmonics; 4G memory, 64G solid-state drive; LCD high brightness TFT LCD touch screen; 10 inches; Resolution 800 × 600; 1 × RS-232/485, 1 × RS232, 4 × USB2.0, 1 × VGA, 1 × GigaLAN.

    Products Advantage

    Technical Level

    • High sampling frequency: 20kHz (sampling time: 83ms → 50ms)
    • More duration time recording: -1~+30s (panoramic recording)
    • More duration time when power loss: 60s
    • Accurate time synchronization function: Beidou or GPS
    • Stronger analysis capabilities: Real time analysis of various voltage issues
    • Solution Recommendation: Based on the analysis results of panoramic recording, recommend the most reasonable solution

    Process Level

    • Change the touch screen to 10 inches
    • Improve wiring methods: wiring terminals, wiring methods, etc
    • High strength anti vibration structural design
    • Artwork style full art design

    Frequently Asked Questions

    QHow does the Beidou/GPS timing feature synchronize with existing systems?

    It can be connected directly to a separate external time synchronization device, or it can share the clock with your original system.

    QWhat trigger conditions initiate immediate recording for voltage anomalies?

    Immediate recording (-1 to +30 seconds) is initiated if the voltage of any phase falls below the set threshold (voltage sag), if the difference between adjacent wave heads exceeds the threshold (voltage flicker), or if voltage oscillations, deviations, surges, grounding, and short circuits occur and exceed configured limits.

    QCan this system replace other routine power quality monitors?

    Yes, it performs routine power quality monitoring including voltage fluctuation, load current, power analysis, THD monitoring, and imbalance monitoring, eliminating the need to install separate monitoring equipment.

    QWhat are the main hardware specifications and interface options?

    The system features a 100kHz sampling frequency, monitors 0-63 harmonics, inter-harmonics, and higher harmonics. It includes 4G memory, a 64G solid-state drive, a 10-inch high-brightness TFT LCD touch screen (800x600 resolution), and multiple ports: 1 × RS-232/485, 1 × RS232, 4 × USB2.0, 1 × VGA, and 1 × GigaLAN.

    QWhat technical advantages does this system offer over standard solutions?

    Key advantages include a high sampling frequency of 20kHz (reducing sampling time from 83ms to 50ms), extended panoramic recording duration (-1 to +30s), prolonged operation during power loss (60s), accurate Beidou/GPS time synchronization, and real-time voltage issue analysis that recommends optimal solutions based on panoramic data.

    QWhat process and structural design improvements have been implemented?

    The design features an upgraded 10-inch touch screen, improved wiring terminals and methods, a high-strength anti-vibration structural design, and an artwork-style full art aesthetic design.

    Leave Your Message