High-Precision RAVS Monitoring Device for Transient Faults in Power Supply - China Suppliers & Factory Offer

Introducing RAVS, an advanced monitoring device meticulously engineered for China's industrial needs, specializing in the online long-term high-frequency recording of sudden voltage changes. As a leading solution among suppliers and factories, RAVS offers real-time monitoring of system voltage, effectively tracking voltage fluctuations and ensuring optimal power quality. With its high accuracy, precision, rapid response, and exceptional stability, RAVS sets the standard for voltage monitoring devices.

Unlike commonly used waveform recorders or power quality monitoring equipment that struggle with capturing short-duration voltage fluctuations, RAVS excels in accurately monitoring and recording prolonged variations in system voltage. It conducts real-time analysis of a range of voltage issues, including flicker, oscillation, deviation, surges, grounding, and short circuits. With its comprehensive recorded analysis, RAVS delivers precise quantitative parameters and practical solutions for fault warnings, analysis, and resolution. Additionally, RAVS can perform real-time online monitoring of conventional power quality metrics such as voltage, current, power, Total Harmonic Distortion (THD), and imbalance, making it an indispensable tool for factories and suppliers across China.

    Functional Features

    No. Feature Description
    1 Beidou/GPS timing Can be connected to a separate external time synchronization device or shared with the original system clock.
    2 Voltage flicker If the difference between the maximum peak values of the two adjacent wave heads of the voltage waveform exceeds the set threshold, immediately start recording (-1~+30s).
    3 Voltage sag If the voltage of any phase is lower than the set threshold, immediately start recording (-1~+30s).
    4 Voltage oscillation Oscillation is difficult to prevent and poses serious harm. When the oscillation amplitude exceeds the set threshold, immediately start recording (-1~+30s).
    5 Voltage deviation The transient voltage waveform contains a DC component, and when the amplitude exceeds the set threshold, the recording is immediately initiated (-1~+30s).
    6 Voltage surge External surge, power transmission, protrusion, sudden load rejection, etc., exceeding the set threshold, immediately start recording (-1~+30s).
    7 Voltage grounding When a single-phase grounding fault occurs in the system, accurately identify the fault and its occurrence time, and immediately start recording (-1~+30s).
    8 Voltage short circuit When a phase to phase short circuit fault occurs in the system, accurately identify the fault and its occurrence time, and immediately start recording (-1~+30s).
    9 Routine power quality monitoring Voltage fluctuation, load current, power analysis, THD monitoring, imbalance monitoring, etc. No need to install other power quality monitors.
    10 Main spec Sampling frequency 100kHz; monitor 0-63 harmonics, inter harmonics, and higher harmonics; 4G memory, 64G solid-state drive; LCD high brightness TFT LCD touch screen; 10 inches; Resolution 800 × 600; one × RS-232/485, 1 × RS232, 4 × USB2.0, 1 × VGA, 1 × GigaLAN.

    Products Advantage

    No Items Main Technical Features
    1 Technical level
    • High sampling frequency: 20kHz (sampling time: 83ms → 50ms)
    • More duration time recording: -1~+30s (panoramic recording)
    • More duration time when power loss: 60s
    • Accurate time synchronization function: Beidou or GPS
    • Stronger analysis capabilities: Real time analysis of various voltage issues
    • Solution Recommendation: Based on the analysis results of panoramic recording, recommend the most reasonable solution
    2 Process level
    • Change the touch screen to 10 inches
    • Improve wiring methods: wiring terminals, wiring methods, etc
    • High strength anti vibration structural design
    • Artwork style full art design
    ROFS, specially designed for low-voltage systems;
    Longer recording time;
    Real time monitoring of circuit breaker status;
    Powerful data analysis and networking capabilities.

    Frequently Asked Questions

    Q What time synchronization methods does the system support?
    The system supports Beidou or GPS timing. It can be connected to a separate external time synchronization device or shared with the original system clock.
    Q How does the device handle voltage anomalies like sags, surges, or oscillations?
    When the system detects that a voltage anomaly (such as sag, surge, oscillation, flicker, deviation, grounding, or short circuit) exceeds the pre-set threshold, it immediately initiates a panoramic recording with a duration of -1 to +30 seconds.
    Q Do I need to install additional power quality monitors alongside this system?
    No, there is no need to install other power quality monitors. This system covers routine power quality monitoring, including voltage fluctuation, load current, power analysis, THD monitoring, and imbalance monitoring.
    Q What are the core technical advantages of the system's technical level?
    It features a high sampling frequency of 20kHz (sampling time: 83ms → 50ms), extended panoramic recording (-1~+30s), a 60s power loss backup duration, real-time analysis of voltage issues, and provides system-recommended solutions based on the recording results.
    Q What hardware specifications does the system offer?
    The main specifications include a 100kHz sampling frequency, monitoring of 0-63 harmonics, inter-harmonics, and higher harmonics. It is equipped with 4G memory, a 64G solid-state drive, a 10-inch high-brightness TFT LCD touch screen (800x600 resolution), and multiple interfaces: 1x RS-232/485, 1x RS232, 4x USB2.0, 1x VGA, and 1x GigaLAN.
    Q What are the specific process level improvements in this version?
    The touch screen has been updated to 10 inches. Wiring methods (wiring terminals, wiring methods, etc.) have been improved, alongside a high-strength anti-vibration structural design and an artwork style full art design.