Functional Features
DCES can effectively compensate for 100% voltage sag.
DCES can effectively address voltage transient problems caused by various power system faults such as single-phase short circuits, interphase short circuits, and three-phase short circuits.
DCES can achieve rapid response of the entire machine within 5ms, and the entire compensation process does not affect the operation of sensitive loads.
DCES can be customized according to user requirements for compensation time, load capacity, and other parameters.
After DCES is turned on, the program will self check and the entire process does not require human intervention. DCES communicates with the user‘s DCS fieldbus through the RS485 interface, uploading the status of the DCES equipment itself and the power supply situation of the power system.
Products Advantage
Segmented synthesis, real-time online, and rapid monitoring technology for AC bus voltage fluctuations and inverter DC voltage fluctuations.
Real time detection of multiple loads and independent protection technology.
Multiple load independent feedback, separate control, and branch output technology.
Intelligent energy management technology can increase shaking protection time by up to 3000%.
Supports up to 4 AC bus voltage fluctuations for simultaneous monitoring.
Supports up to 96 independent outputs.
Detail Pictures
Frequently Asked Questions
How fast can the DCES respond to voltage fluctuations?
The DCES achieves an ultra-rapid response within 5ms across the entire unit, ensuring that sensitive loads remain completely unaffected throughout the voltage compensation process.
Can the DCES fully compensate for a complete voltage drop?
Yes, the system is engineered to effectively compensate for 100% voltage sag and resolve transient problems caused by single-phase, interphase, and three-phase short circuit faults.
How does the DCES integrate with industrial automation systems?
DCES runs self-diagnostic routines automatically upon startup and communicates with the user's DCS fieldbus through an RS485 interface, reporting equipment status and power supply real-time conditions without requiring manual intervention.
Can compensation time and capacity be customized to specific needs?
Yes, DCES can be tailored according to specific operational parameters, including load capacity, compensation duration, and unique user requirements.
How many AC buses and independent outputs can be supported?
The system can simultaneously monitor voltage fluctuations across up to 4 AC buses and support up to 96 independent branch outputs with separated control and feedback.