Multifunctional TOVS Power Interference Suppression Device - China Suppliers & Factory for Lightning Protection
-
✔
Over 90% attenuation of overvoltage caused by lightning strikes, operation, resonance, etc.
-
✔
Simultaneously solving various problems such as normal interference and transient interference.
-
✔
Does not conflict with SPD, and the original system can remain unchanged.
-
✔
TOVS is generally installed in the output of UPS to clear its interferences.
-
✔
The maximum amplitude is limited to below 370V, which is the peak value of 260V.
-
✔
The interference attenuation efficiency is greater than 90%.
-
✔
TOVS can fill the huge protection blind spot of SPD.
-
✔
TOVS can also be installed on the input end of UPS for protection.
-
✔
TOVS has multiple overvoltage protection functions to ensure the safety of electrical equipment.
-
⚠
When there is a minor malfunction in the TOVS device, the device has a fault alarm function, and the [Alarm] indicator light is on for maintenance personnel to check. The TOVS device has an alarm and some functions are missing. The main functions are still effective and do not affect the safe and reliable operation of the load.
| Suppression frequency range | 75Hz~100MHz |
| Maximum suppression current | 120kA (8/20us) |
| Maximum suppression voltage | 25kV(8/20us) |
| Continuous operating current | ≤20A |
| Loss | <60W |
| Interference suppression rate | 50%~96% |
| Response time | <25ns |
| Resistance measurement range | 0-200Ω |
| Measurement accuracy | ±2.5% |
What is the primary function of the TOVS device?
TOVS provides multiple overvoltage protection functions, achieving over 90% attenuation of overvoltage caused by lightning strikes, operation, and resonance, while simultaneously solving normal and transient interference problems.
Does TOVS conflict with existing Surge Protective Devices (SPD)?
No, TOVS does not conflict with SPD. The original system can remain unchanged, and TOVS helps to fill the large protection blind spots inherent in standard SPD systems.
Where should the TOVS device be installed?
TOVS is generally installed at the output end of a UPS to clear its interferences, but it can also be installed at the input end of the UPS for protection purposes.
What happens if the TOVS device encounters a minor malfunction?
If a minor malfunction occurs, the fault alarm function activates and the [Alarm] indicator light turns on. While some functions may be missing during an alarm, the main functions remain effective, ensuring the safe and reliable operation of the load is not affected.
What are the key electrical limits of the TOVS?
The maximum amplitude is limited to below 370V (the peak value of 260V), with a response time of less than 25ns, and a continuous operating current limit of ≤20A.
What is the measurement accuracy and range of the TOVS device?
The TOVS device features a resistance measurement range of 0-200Ω with a measurement accuracy of ±2.5%.