Leave Your Message
Products Categories
Featured Products

RAVS: Advanced China Factory Supplier for Real-Time High-Frequency Power Supply Voltage Monitoring Solutions

RAVS is an advanced monitoring device crafted specifically for real-time, long-term high-frequency recording of sudden voltage changes in systems. As a top choice among China suppliers, RAVS excels in providing precise monitoring of system voltage, effectively capturing voltage fluctuations and ensuring optimal power quality. With its high accuracy, precision, rapid response, and stability, it stands out as a reliable solution for industries requiring stringent voltage supervision.

Unlike conventional waveform recorders or power quality monitoring devices available in the market, RAVS accurately tracks and records short-duration voltage fluctuations over extended periods. It enables real-time analysis of critical voltage issues such as flicker, oscillation, deviation, surge, grounding, and short circuits. This intelligent device offers precise quantitative parameters that assist in fault warnings, comprehensive fault analysis, and effective resolution strategies. Moreover, RAVS supports real-time online monitoring of essential conventional power quality metrics, including system voltage, current, power, THD, and imbalance, making it an indispensable tool for factories seeking to enhance their power management systems.

    Functional Features
    Beidou/GPS timing
    01
    Can be connected to a separate external time synchronization device or shared with the original system clock.
    Voltage flicker
    02
    If the difference between the maximum peak values of the two adjacent wave heads of the voltage waveform exceeds the set threshold, immediately start recording (-1~+30s).
    Voltage sag
    03
    If the voltage of any phase is lower than the set threshold, immediately start recording (-1~+30s).
    Voltage oscillation
    04
    Oscillation is difficult to prevent and poses serious harm. When the oscillation amplitude exceeds the set threshold, immediately start recording (-1~+30s).
    Voltage deviation
    05
    The transient voltage waveform contains a DC component, and when the amplitude exceeds the set threshold, the recording is immediately initiated (-1~+30s).
    Voltage surge
    06
    External surge, power transmission, protrusion, sudden load rejection, etc., exceeding the set threshold, immediately start recording (-1~+30s).
    Voltage grounding
    07
    When a single-phase grounding fault occurs in the system, accurately identify the fault and its occurrence time, and immediately start recording (-1~+30s).
    Voltage short circuit
    08
    When a phase to phase short circuit fault occurs in the system, accurately identify the fault and its occurrence time, and immediately start recording (-1~+30s).
    Routine power quality monitoring
    09
    Voltage fluctuation, load current, power analysis, THD monitoring, imbalance monitoring, etc. No need to install other power quality monitors.
    Main spec
    10
    Sampling Frequency: 100kHz
    Monitoring: 0-63 harmonics, inter harmonics, and higher harmonics
    Memory & Storage: 4G memory, 64G solid-state drive
    Display: LCD high brightness TFT LCD touch screen; 10 inches; Resolution 800 × 600
    Interfaces: 1 × RS-232/485, 1 × RS232, 4 × USB2.0, 1 × VGA, 1 × GigaLAN
    Products Advantage
    Technical Level
    High sampling frequency: 20kHz (sampling time: 83ms → 50ms)
    More duration time recording: -1~+30s (panoramic recording)
    More duration time when power loss: 60s
    Accurate time synchronization function: Beidou or GPS
    Stronger analysis capabilities: Real time analysis of various voltage issues
    Solution Recommendation: Based on the analysis results of panoramic recording, recommend the most reasonable solution
    Process Level
    Change the touch screen to 10 inches
    Improve wiring methods: wiring terminals, wiring methods, etc
    High strength anti vibration structural design
    Artwork style full art design
    ROFS, specially designed for low-voltage systems;
    Longer recording time;
    Real time monitoring of circuit breaker status;
    Powerful data analysis and networking capabilities.
    Frequently Asked Questions (FAQ)
    What are the time synchronization options supported by the system?
    The system features Beidou/GPS timing. It can be connected to a separate external time synchronization device or shared with the original system clock to ensure high-accuracy time synchronization.
    How does the device handle voltage anomalies like sags, surges, and flickers?
    When the device detects voltage anomalies (such as sags, surges, flickers, oscillations, deviations, grounding, or short circuits) exceeding the set threshold, it immediately initiates recording with a recording duration of -1 to +30 seconds.
    Does this system require additional power quality monitors for routine checks?
    No, there is no need to install other power quality monitors. The device supports routine power quality monitoring, including voltage fluctuation, load current, power analysis, THD monitoring, and imbalance monitoring.
    What are the core hardware and interface specifications?
    The device is equipped with a 10-inch high-brightness TFT LCD touch screen (800 × 600 resolution), a 100kHz sampling frequency, 4G memory, 64G SSD storage, and multiple interfaces including 1 × RS-232/485, 1 × RS232, 4 × USB2.0, 1 × VGA, and 1 × GigaLAN.
    What technical advantages does this system offer over standard options?
    Key technical advantages include a high sampling frequency of 20kHz, extended panoramic recording (-1~+30s), 60 seconds of backup power during power loss, Beidou/GPS time synchronization, real-time voltage analysis, and automated solution recommendations based on panoramic recording.
    Is the ROFS system suitable for low-voltage setups?
    Yes, ROFS is specially designed for low-voltage systems. It features longer recording times, real-time monitoring of circuit breaker status, and powerful data analysis and networking capabilities.

    Leave Your Message