01
Smart IGES Grounding System for Substations - China Suppliers & Factory Solutions for Safety Monitoring
The main functions of the IGES intelligent ground grid warning and defense system include:
Online Protection
Providing online protection functions such as secondary overvoltage, ground potential counterattack overvoltage, and ground grid interference suppression.
Real-Time Monitoring
Provide real-time data monitoring function for important parameters such as grounding impedance, grounding current, grounding grid potential, and spectrum analysis.
Pre-Alarm System
Provide pre alarm functions such as grounding impedance exceeding limit, ground potential exceeding limit, power supply voltage and current exceeding limit, etc.
Digital Management Platform
Provide a digital management platform, providing online display of major electrical parameter data and waveforms, historical records, important event records, warning and defense, etc.
Functional features
- Secondary equipment room: Ground grid status monitoring and warning
- Secondary equipment room: Grounding potential overvoltage attack suppression
- Secondary equipment room: AC overvoltage transient recording and suppression
- Secondary equipment room: DC overvoltage transient recording and suppression
- HV incoming line Ⅰ: Lightning arrester monitoring and warning
- HV incoming line Ⅱ: Lightning arrester monitoring and warning
- Transformer Neutral: Lightning arrester monitoring and warning
products advantage
- Addressing security vulnerabilities in substations
- Adopting a high-performance embedded hardware platform
- Based on the concept of distributed module combination design, it facilitates on-site installation by users
- Digital interface based on IEC61850 facilitates the implementation of digital substations
- Adopting a high-performance 32-bit microprocessor+dual DSP hardware structure, multiple processors work in parallel, with a maximum sampling rate of 200kHz
- Fine tuned design, strong electromagnetic compatibility, safe and reliable, simple screen assembly, and convenient operation and maintenance
detail pictures
Frequently Asked Questions
What protection capabilities does the IGES system provide?
It provides comprehensive online protection functions including secondary overvoltage, ground potential counterattack overvoltage, and ground grid interference suppression.
Which electrical parameters are monitored in real time?
The system continuously monitors critical parameters such as grounding impedance, grounding current, grounding grid potential, and performs spectrum analysis.
What pre-alarm triggers does the system feature?
Pre-alarm functions are triggered by grounding impedance exceeding limits, ground potential exceeding limits, and power supply voltage or current exceeding limits.
What components are monitored in the HV incoming lines and transformers?
The system provides lightning arrester monitoring and warning for HV incoming line Ⅰ, HV incoming line Ⅱ, and the Transformer Neutral.
What is the hardware structure and sampling performance of IGES?
The system features a high-performance 32-bit microprocessor with a dual DSP hardware structure working in parallel, achieving a maximum sampling rate of 200kHz.
Does the IGES system support digital substation standard interfaces?
Yes, it features a digital interface based on IEC61850, facilitating seamless integration and implementation within digital substations.