01
VTIS Power Supply Protection for Circuit Breakers - Reliable Secondary Control Solutions from China Suppliers and Factory
Functional Features
- Normal start and stop will not delay, and the circuit breaker will only delay when there is voltage fluctuation;
- Equipped with voltage fluctuation recording and searching function, capable of recording the last 10 fluctuation times;
- When the module malfunctions, it does not affect the normal operation of the circuit;
- Equipped with hardware voltage fluctuation/power outage identification circuit, used to distinguish between voltage drop faults and normal power outages.
Products Advantage
- VTIS can provide dual protection against voltage fluctuations and interference for circuit breaker control power supply;
- The VTIS wiring method is simple and convenient, without the need for significant changes to the circuit;
- Supercapacitor energy storage has the advantages of long service life, short charging time, high discharge current, multiple cycles of charging and discharging, no memory effect, and simple charging control circuit;
- The series interference suppression module has multiple electrical safety active defense functions, including lightning overvoltage suppression, ground potential counterattack overvoltage suppression, operation overvoltage suppression, resonance overvoltage suppression, voltage temporary rise regulation, and load interference suppression;
- VTIS has a hardware voltage fluctuation/power outage identification circuit, used to distinguish between voltage drop faults and normal power outages.
Detail Pictures
Frequently Asked Questions
Will normal start and stop operations cause a delay?
No, normal start and stop will not delay. The circuit breaker will only delay when there is voltage fluctuation.
How many voltage fluctuation events can the system record?
The system is equipped with a voltage fluctuation recording and searching function capable of recording the last 10 fluctuation times.
What happens if the module malfunctions?
When the module malfunctions, it does not affect the normal operation of the circuit.
What are the advantages of the supercapacitor energy storage?
Supercapacitor energy storage has the advantages of long service life, short charging time, high discharge current, multiple cycles of charging and discharging, no memory effect, and a simple charging control circuit.
How does VTIS distinguish between voltage drop faults and normal power outages?
VTIS is equipped with a hardware voltage fluctuation/power outage identification circuit specifically used to distinguish between voltage drop faults and normal power outages.