VTIS Secondary Control System Power Supply & Breaker Protection - Trusted China Suppliers & Factory Solution
Functional features
- Normal start and stop will not delay, and the circuit breaker will only delay when there is voltage fluctuation;
- Equipped with voltage fluctuation recording and searching function, capable of recording the last 10 fluctuation times;
- When the module malfunctions, it does not affect the normal operation of the circuit;
- Equipped with hardware voltage fluctuation/power outage identification circuit, used to distinguish between voltage drop faults and normal power outages.
Products advantage
- VTIS can provide dual protection against voltage fluctuations and interference for circuit breaker control power supply;
- The VTIS wiring method is simple and convenient, without the need for significant changes to the circuit;
- Supercapacitor energy storage has the advantages of long service life, short charging time, high discharge current, multiple cycles of charging and discharging, no memory effect, and simple charging control circuit;
- The series interference suppression module has multiple electrical safety active defense functions, including lightning overvoltage suppression, ground potential counterattack overvoltage suppression, operation overvoltage suppression, resonance overvoltage suppression, voltage temporary rise regulation, and load interference suppression.
- VTIS has a hardware voltage fluctuation/power outage identification circuit, used to distinguish between voltage drop faults and normal power outages.
Detail pictures
Frequently Asked Questions
Q1: How does VTIS handle normal start and stop operations?
Normal start and stop operations will not experience any delay. The circuit breaker will only initiate a delay response when actual voltage fluctuations are detected.
Q2: Can the VTIS system record voltage fluctuation events?
Yes, it features a voltage fluctuation recording and searching function, which is capable of recording the details of the last 10 fluctuation events.
Q3: What happens to the circuit if the VTIS module malfunctions?
If the module malfunctions, it is designed not to affect the normal operation of the main circuit, ensuring continuous system reliability.
Q4: How does VTIS distinguish between a fault and a normal power outage?
VTIS is equipped with a dedicated hardware voltage fluctuation/power outage identification circuit that accurately distinguishes between voltage drop faults and normal power outages.
Q5: What are the main benefits of using supercapacitors in VTIS?
The supercapacitor energy storage offers a long service life, short charging times, high discharge currents, multiple charge-discharge cycles, no memory effect, and a simplified charging control circuit.
Q6: What active electrical safety defenses does the suppression module offer?
The series interference suppression module provides multiple active defenses, including protection against lightning, ground potential counterattack, operation, and resonance overvoltages, alongside voltage temporary rise regulation and load interference suppression.